    Was at this machine today shows E30 fault code, i suspect it is pressure sw related but not sure i have checked for blockages, wiring etc when the door is shut E30 pops up and door lock cylces on and off, i would be gratefull for any help cheers jj.

    #248045
    Martin
    Participant

    Re: Zanussi ZJ1218

    All Zanussi errors starting with E3? are associated with Pressure Switch/Overfill/Blocked Pressure System faults you will find 😉

    #248046
    johnnyj
    Participant

    Re: Zanussi ZJ1218

    Thanks Martin i’ll try a press sw as threre doesnt seem to be any blockages.

    #248047
    admin
    Keymaster

    Re: Zanussi ZJ1218

    Try easiest way first: check heater for earth leakage (measure between each heater connector on both polarity)… and you will be surprised 😯 😆 😉
    or change pressure switches