ParticipantHi,
I have an RLA30 Fridge that is just over 2 years old. Recently we noticed that things seem to be getting very cold – it froze some chicken last week!
First assumed that 3yo son had messed with the control, but it’s on ‘3’ as usual.
Over at least the last couple of weeks, whenever I go to the fridge, the compressor is running. If I move the stat down the tiniest fraction, it stops. If I turn it back up to max (or down to min?) nothing happens, suggesting -to me anyway- that the temperature is below the minimum.
It seems that the contacts on the stat are ‘sticking’ once they close, causing the compressor to run permanently until it gets a nudge. I can’t see a replacement stat in the shop – is one available?
BTW – To confirm my suspicions I intend to borrow a datalogger + thermocouple this evening and monitor the temperature overnight to see what’s happening. If interesting, I’ll post the results.
Hope someone can help…
Thanks,
Simon
April 14, 2008 at 7:04 pm #249051Penguin45
ParticipantRe: Hotpoint RLA30 Thermostat not switching off??
Sounds like a stat failure to me….. Full model number and serial number required to identify as there are early and late thermostats.
Penguin45.
April 15, 2008 at 9:30 am #249052SiHa
ParticipantThanks Mr Penguin.
FYI, I measured it overnight and wouldn’t you know, it seeemed to be working fine! The middle shelf went from 4°C to 1°C on roughly a 3-hour cycle, with the top being +2° and the bottom shelf -1°. Both middle & bottom shelves touched -1°C but only for about 1/2 hr.
Sounds normal to me…
Whatever – I’m sure the stat’s on it’s way out, so I’ll check the plate when I get back home for full info and post back.
Cheers,
Simon
April 16, 2008 at 11:37 am #249053SiHa
ParticipantRe: Hotpoint RLA30 Thermostat not switching off??
Penguin45 wrote:Full model number and serial number required
P45 -That’s an unfortunate abbreviation…
Model RLA30S
S/N 40090094
IND Code 76 31505 0000Cheers 😀
April 16, 2008 at 9:11 pm #249054Penguin45
ParticipantRe: Hotpoint RLA30 Thermostat not switching off??
SiHa wrote:P45 -That’s an unfortunate abbreviation…
Don’t you start….. 😆
Stat should be 2603392 – spares@ukwhitegoods.co.uk will get you one promptly.
Penguin45.
April 17, 2008 at 9:25 am #249055SiHa
ParticipantGreat stuff, thanks!
emailing now…
July 9, 2012 at 6:46 pm #249056vince69619
ParticipantRe: Hotpoint RLA30 Thermostat not switching off??
I need to know which stat to get please, my fridge details are;
RLA30P
Serial – 14105628Thanks
Vince. -