    Does anyone know whether or not the Lofra Electric and Gas Oven Range Cooker – CD96GGE/C – needs hard wiring, or does it come with a standard 13 amp plug?
    Any info on this would be much appreciated.

    #249791
    Phidom
    Participant

    Re: Electrical connection for Lofra range cooker

    I don’t know this particular make but the rule of thumb is single electric ovens only need a 13 amp supply but double ovens need to be hard wired. As it is a range cooker I should think it has 2 or more ovens so it will be hard wired with 6mm cable and a 40 amp double pole isolating switch. If you went for an all electric range cooker you would probably need to have 10mm cable.

    #249792
    Phidom
    Participant

    Re: Electrical connection for Lofra range cooker

    Sorry, just looked up the spec. of this appliance and it has both a gas and an electric oven so it is effectively a single oven for electrical purposes. The oven elements total less than 3 Kw so it will be a 13 amp supply.

    #249793
    Rookie
    Participant

    Re: Electrical connection for Lofra range cooker

    Thank you for your generous response – the extra info is extremely useful. At present we only have an old freestanding gas cooker (inherited with our new house) and don’t particularly want to install a new cooker point.