hotpoint bfi620

Viewing 4 posts - 1 through 4 (of 4 total)
  • Author
    Posts
  • #36589
    pete2671
    Participant

    hello, my machine pumps water in and then will not work the cycle indicator lights have 2 flashing 2nd and 4th. I had a hotpoint engineer fit me a heater element in january but am reluctant to call them if its not the problem. Is there anything else I can check?
    Thank you.

    #251594
    iadom
    Moderator

    Re: hotpoint bfi620

    2 + 4 is a ‘no heat’ fault. If the heater has failed it will be under guarantee.

    The control PCB is also a very common cause of heater failure on these machines. You cannot check that.

    Jim.

    #251595
    pete2671
    Participant

    Re: hotpoint bfi620

    when I pull the machine out and tilt it water comes out of the base I have read that this could mean an internal leak, is there a part I could check for this?

    #251596
    iadom
    Moderator

    Re: hotpoint bfi620

    A flooded base should cause the drain pump to run continuously and give a different error code.

    Several things could cause a leak, even a badly fitted heater 😉

    It can also be caused by oversoaping due to using 3 in 1 tablets.

    Jim.

Viewing 4 posts - 1 through 4 (of 4 total)