BOSCH KGV3120GB/03 F/FREEZER Home › Forums › Trade Technical & Spare Parts Forums › Trade Technical Enquiries › BOSCH KGV3120GB/03 F/FREEZER This topic has 4 replies, 2 voices, and was last updated 17 years, 10 months ago by mbdas. Viewing 5 posts - 1 through 5 (of 5 total) Author Posts May 28, 2008 at 3:20 pm #37017 mbdasParticipant Hi 🙂 Im having a time with this machine 😳 It cools down ok for a few days and then defrosts it self Ive changed the module but still the same no better or worse any help at this point would be helpfull 😳 Thanks Mark 🙂 May 28, 2008 at 6:23 pm #253134 gegsyParticipant Re: BOSCH KGV3120GB/03 F/FREZER Its the well known foamed in NTC fault 😀 Module will make no difference. Check your email 😉 Greg May 29, 2008 at 12:28 pm #253135 mbdasParticipant Re: BOSCH KGV3120GB/03 F/FREEZER Thanks Greg 😀 😀 I will let you know how it goes 🙂 Not going till Monday 🙂 Mark 🙂 June 5, 2008 at 12:49 pm #253136 mbdasParticipant Re: BOSCH KGV3120GB/03 F/FREEZER THANKS GREG 😀 Just got off the phone with a happy customer its working great she said 🙂 Mark 😀 😀 June 5, 2008 at 6:07 pm #253137 gegsyParticipant Re: BOSCH KGV3120GB/03 F/FREEZER Excellent :tup: Greg Author Posts Viewing 5 posts - 1 through 5 (of 5 total) You must be logged in to reply to this topic. Log In Username: Password: Keep me signed in Log In