    Last Friday I noticed the fridge was dead an light not on. Wifey was demanding, whilst holding a rolling pin, that I fix it so, checked socket and plug etc and all ok.
    Changed stat and it worked. Although light still off so checked bulb and its dead. Now the firdge works but ice is forming on inside back of fridge no matter what setting you have stat on.

    4 years old

    Only 3 connectors on stat and one of them is earth so cant’ do wrong, or can I?
    Used a universal stat as per shop ex engineer say so

    Any help appriiciated and could save my life or a severe battering from my old gal. 🙁

    #254166
    helo_75
    Participant

    ice is supposed to form on the back of the fridge, we’ve had this discussion before

    its perfectly normal. id only start worrying if it freezes your food

    hope this helps

    #254167
    Dales-Electronic
    Moderator

    Re: Hotpoint RLA84 Dead

    Is the ‘universal stat’ a VT9/VL9 and if so which wires have you connected to what?

    #254168
    toby150
    Participant

    Re: Hotpoint RLA84 Dead

    The ice forms on the inside back of fridge and has not done it on such a scale in 4 years. Looks like snow about 1/4 inch hick. Also water in jug is freezing up when stat is on 1. We used to have old sat on no. 3 for 4 years and no freezing

    Universal stat is a VARIFIX VC1 as supplied by engineer in shop saying all enginners use em??????
    It only as 3 connections. one is obviouse to me an earth :rolls: (I am ex engineer level but not fidges) The back connecetor has live brown on it and the front connector has a white wire. When i say front I mean near stat adjustment knob.

    Thanks for taking time to reply. Mucho appriciated 😀

    #254169
    Washman
    Participant

    Re: Hotpoint RLA84 Dead

    Hi

    VC1 is wrong stat, its used on fridges with ice compartment you need a stat for a fridge that defrosts rear plate before fridge cuts back in. As Dales Electronic says a VT9 or VL9 depending on type of fridge

    Mike

    #254170
    toby150
    Participant

    Re: Hotpoint RLA84 Dead

    Cheers Mike I will take it back to shop in the morno and see what he says to that. He did give me the old “I have been an enginner for years” and I did tell him what model it was so this is interesting


    Thank You
    to all


    Dave 😆

    #254171
    toby150
    Participant

    Re: Hotpoint RLA84 Dead

    Just looked at original stat and it does indeed have 4 connection ponts. Mind u I took a photo of it before removal and it only has the two outer ones in use plus the earth. The middle one was not used????

    #254172
    toby150
    Participant

    Re: Hotpoint RLA84 Dead UPDATE

    Have this morno put the crorrect stat in, but still no change. Ths snowy ice is still on the inside back wall. The fridge is now switched off awaiting the defrost to perhaps try again.

    Heater area perhaps?

    Any further help greatly appricated

    Dave

    #254173
    Simon46
    Participant

    Re: Hotpoint RLA84 Dead

    Wiring colours to what pins please? Unplug power first.

    S.

    #254174
    toby150
    Participant

    Re: Hotpoint RLA84 Dead

    pin 3 has brown wire. This also has a piggy back brown attached to it.

    Earth to obvious earth metal casing around stat or “B” pin.

    Pin 4 has two spade flats and I have connected white wire to the top one i.e if you hold the stat with adjuster knob facing you with thermo tube at the left

    pin 6 is just an empty socket

    b4 taking old stat off I photographed it to ensure it went back the same way.

    Hope this helps

    Cheers

    Dave

    #254175
    helo_75
    Participant

    well, heres potential bad news

    ive put a compressor on one of those today for exactly that, it was a weak pumping compressor

    let us know how you go on

    #254176
    toby150
    Participant

    Re: Hotpoint RLA84 Dead

    Oh Dear as head bounced off wifeys rolling pin

    Would it not produce any ice if the comp was gone or weak?

    #254177
    expertcat
    Participant

    If its a vt9 an only to wires try connecting on pin 4 and pin 6

    Pin 3 will be permantly live and is only a light connection.

    Pin4 will be live
    Pin 6 will be compressor feed.

    At the moment if you are using pin 3 & 4 it will run all the time as the thermostat will not let the unit cycle.

    #254178
    toby150
    Participant

    Re: Hotpoint RLA84 Dead

    Many Thanks for that but in the end I put the old stat back in and the fridge is now working 100{e5d1b7155a01ef1f3b9c9968eaba33524ee81600d00d4be2b4d93ac2e58cec2d} No ice. No idea what that was all about whatsoever but hey ho, thats engineering I spose so watch this space

    Thanks to all who tried to help

    Dave