    bluejack
    Participant

    [b]hi ive got a problem with an indersit wi 101 i dont think its heating up ive checked the heater and thermister with a meter they are ok . when i put programe 1 a 90 degree wash it fills up then empties again then the program timer goes around on its own ,any ideas thanks

    #255232
    smartin
    Participant

    Re: indersit wi 101

    when the timer starts clicking round the on light will be flashing on and off in quick succession count the number of flashes as that relates to a fault code

    smartin

    #255233
    bluejack
    Participant

    Re: indersit wi 101

    hi there are 7 flashes followed by a long pause then 7 flashes, thanks .

    #255234
    smartin
    Participant

    Re: indersit wi 101

    means heater relay stuck, i would double check heater and wires if all is ok then would be a pcb and eeprom obviously unplug before checking

    #255235
    bluejack
    Participant

    Re: indersit wi 101

    thanks,

    #255236
    gegsy
    Participant

    Re: indersit wi 101

    Moved to Trade section 😉

    Greg

    #255237
    johnnyj
    Participant

    Re: indersit wi 101

    Check for a dry joint on the module at the heater relay, this can cause this fault also.