    Hi
    Can any one help ,when you put this dryer on to tumble it only goes for sabout 3 minutes and then goes to zero(0) and bleeps 3 times intermittent
    Im baffled

    #255879
    A1engineer
    Participant

    Re: siemens siwathern 7902 tumble dryer

    have a look inside if it is the one fitted with a light look to see if the lens is missing, had a few of these with the lense missing condensation gets into board and machine does funny things.

    #255880
    eastlmark
    Moderator

    Re: siemens siwathern 7902 tumble dryer

    If its a condenser it could well be blocked. Check also it is heating as it may shut down if no heat rise detected.

    #255881
    sandysuds
    Participant

    Re: siemens siwathern 7902 tumble dryer

    Hi guys
    This dryer is still giving me a headache, when started laundry dry stays on then the dryer goes for about 3 mins and then goes to zero and bleeps , i have checked heating side ok. can anyone help

    #255882
    gegsy
    Participant

    Re: siemens siwathern 7902 tumble dryer

    Can you get model off the door frame. 🙂

    Greg

    #255883
    superfix
    Participant

    Re: siemens siwathern 7902 tumble dryer

    Are you testing it empty or with a load ?.

    If it’s a sensor dryer it WILL need a damp load for it to work.