  • #38133
    rocker
    Participant

    machine takes in some water, then drains a small amount, then nothing.
    set on 90deg cycle. there is no negitive to hot valve ??
    have fitted pcb from Tony at emw..same fault. Tony has advised me to fit a new pressure s/w…ordered today. the reason I am asking is if that fails to resolve fault..anyone gone any idea what else to look for.
    Cheers John

    #257820
    wilf
    Participant

    Re: Indesit W161UK

    check the valve resistances a short would bring on the pump if its used as a ballast

    wilf

    #257821
    helo_75
    Participant

    ahem

    theyre supposed to drain after taking water

    its the test program!

    it wil fill test components, including pump

    if it doesnt carry on after 30 seconds, its likeley to be the cold inlet
    it doesnt take hot water , only on its second actual fill
    one of your valves is faulty, me thinks

    other than that, yes its the pcb

    #257822
    rocker
    Participant

    Re: Indesit W161UK

    Thanks to both of you for advice. John