Creda W220vw

Viewing 4 posts - 1 through 4 (of 4 total)
  • Author
    Posts
  • #38247
    PGS
    Participant

    Had call from customer saying the end light is on constant and prog cannot be selected. She had a new interlck fitted from competitor 1 week ago, Any ideas before i call cheers . PCB?

    #258193
    iadom
    Moderator

    Re: Creda W220vw

    Sent you some ‘stuff’ 😉

    Jim.

    #258194
    PGS
    Participant

    Re: Creda W220vw

    Thanks Jim, The board will not accept any commands. Im going to fit a EMW board when it arrives. Thankyou for info.

    #258195
    burns
    Participant

    Re: Creda W220vw

    If Jims not already covered it, fact the door switch has changed its possible if fitting the new switch they have got the plug the wrong way or the right way for the old switch but wrong for the new type.
    This will take out the board.

    Check it out before fitting a new board just in case.

Viewing 4 posts - 1 through 4 (of 4 total)