comp horsepower

Viewing 7 posts - 1 through 7 (of 7 total)
  • Author
    Posts
  • #38928
    robbo1973
    Participant

    hi can anyone tell me the h/p of this pot

    acc hsh115aa

    cheers chris

    #260364
    BobHope
    Participant

    Re: comp horsepower

    Hi Chris

    give us a clue, make, model, fridge, freezer, fridge freezer, ?
    compressor manufacurer and type of refrigerant.

    Bob.

    ps, i do have charts to compare but thats not on them.

    #260365
    robbo1973
    Participant

    Re: comp horsepower

    sorry the make is the acc (or that is what it looks like) r600a fitted to a servis f/frzr not sure on model at mo.

    #260366
    lerch
    Participant

    Re: comp horsepower

    Hi bobhope any chance of a copy of the chart as I am always getting asked and that would make my life alot easier. 😀

    #260367
    admin
    Keymaster

    Re: comp horsepower

    Heres’ how I use the R600A compressors :

    1/8 small under counter fridges
    1/6 under counter freezers & upto 4′ fridges
    1/5 4′ & above fridges and upto 5′ fridge freezers
    1/4 anything larger than above

    Bryan

    #260368
    lerch
    Participant

    Re: comp horsepower

    thanks 😀

    #260369
    Alex
    Participant

    Re: comp horsepower

    Look at the rating plate for the watts consumed. Divide by 746 and you get a rough H.P. I know the heater is included, but the plate should give the total power consumed at any given time, and ideally the d/f heater won’t be on at the same time as the compressor. In any case you err on the side of caution. The lamp is usually 15w if you want to be precise.

    Bryans chart as above is a good yardstick.

    Alex

Viewing 7 posts - 1 through 7 (of 7 total)