Zanussi/electrolux WJD1667W Home › Forums › Trade Technical & Spare Parts Forums › Trade Technical Enquiries › Zanussi/electrolux WJD1667W This topic has 2 replies, 2 voices, and was last updated 17 years, 6 months ago by rocker. Viewing 3 posts - 1 through 3 (of 3 total) Author Posts October 13, 2008 at 7:41 pm #40189 rockerParticipant There is a fault code E10 when on tumble dryer cycle, have looked in fault codes but not sure which one relates to this model, as this model has a EWM2000 Pcb. according to connect site. Thanks John October 13, 2008 at 7:47 pm #265061 helo_75Participant the green coil is faulty on the 3 way valve worth checking the condenser for blockages as well you can change the whole valve if u ike, or just change the green coil ( thats what i do) October 13, 2008 at 8:25 pm #265062 rockerParticipant Re: Zanussi/electrolux WJD1667W Helo many thanks John. Author Posts Viewing 3 posts - 1 through 3 (of 3 total) You must be logged in to reply to this topic. Log In Username: Password: Keep me signed in Log In