  • #40233
    rocker
    Participant

    Fitted a new motor last week, machine somtimes wont start or starts and runs for a while then stops, press the start button (dead) wait a while then may start again, not sure what to look for on this machine, could it be the start S/W or electronic part overheating..
    drum runs freely
    can anyone please advise me as to possible cause.
    Cheers John.

    #265201
    Washman
    Participant

    Re: Whirlpool 3RLEC8646KQ (USA) T/D

    Hi

    I had this problem not long ago. Changed motor still no go , then found on fan duct at the back there is a thermal fuse and a thermostat with 4 connections the motor feeds through middle part of this stat . Changed both and machine has been working Ok for 4 weeks now , in a nursing home , so gets a lot of use.

    Part no should be 481925228095 thermal fuse
    Part no 481928248311 thermostat

    Mike

    #265202
    rocker
    Participant

    Re: Whirlpool 3RLEC8646KQ (USA) T/D

    Cheers Mike, glad you advised me on this, as I was concerned I couldn’t find fault, this machine also get a lot of use in a day nursery.

    John.

    #265203
    eastlmark
    Moderator

    Re: Whirlpool 3RLEC8646KQ (USA) T/D

    think some of those have a microswitch on the belt pulley that cuts the motor if the belt fails. Could possibly have a problem there.

    #265204
    rocker
    Participant

    Re: Whirlpool 3RLEC8646KQ (USA) T/D

    Eastlmark, you are correct, when I fitted new motor I checked this mirco out I am sure this is ok. many thanks for your help.
    John

    #265205
    rocker
    Participant

    Re: Whirlpool 3RLEC8646KQ (USA) T/D

    Been back to check thermostat & Toc all ok. feel it may be the start switch, which must in turn activate a relay (somewere) but not sure how to test this part, or were relay is suituated. can anyone help please. John

    #265206
    EFS
    Participant

    Re: Whirlpool 3RLEC8646KQ (USA) T/D

    The relay is integral with the start switch and is straight forward to test.
    The most likely cause of the symptom described is the TOC inside the motor which will reset itself when the motor cools down.
    The four terminal thermostat only controls temperature.
    The two smaller terminals are a small heating resistance which makes the thermostat open more frequently when low temp is selected

    Hope this helps.

    Steve

    #265207
    rocker
    Participant

    Re: Whirlpool 3RLEC8646KQ (USA) T/D

    Steve, thanks for your reply, as I have fitted a new motor and its free running and with no load, cant see any reason why the internal TOC should activate.


    John.

    #265208
    EFS
    Participant

    Re: Whirlpool 3RLEC8646KQ (USA) T/D

    There should be a circuit diagram hidden inside the cabinet usually under the control panel. 😉
    Should be easy to follow.

    Good luck

    Steve

    #265209
    rocker
    Participant

    Re: Whirlpool 3RLEC8646KQ (USA) T/D

    Cheers Steve, will look for this, sorry for late reply. John