    when u turn on machine and pick a program, the pump pulses for 5 10 seconds then fills, after fill the motor and pump both pulse 240v.

    the motor turns slightly then stops hence the pulse

    ne ideas?

    #266343
    Steven
    Participant

    Re: LI62UK D/W PULSING

    Have you checked the start capacitor first?

    I had an indesit, with a similar problem it turned out to be a circulation motor.
    This was after going out to with a reported fault no heat.

    I found the drain hose had a pin hole leak which flooded base, the tubular element was blown to pieces, so did not suspect the motor.

    It would start to pulse half way through program, by doing so was heating up like a coffee perculator, which was why the element blew in the first place.