ctd00 Home › Forums › Trade Technical & Spare Parts Forums › Trade Technical Enquiries › ctd00 This topic has 4 replies, 3 voices, and was last updated 17 years, 5 months ago by robbo1973. Viewing 5 posts - 1 through 5 (of 5 total) Author Posts November 3, 2008 at 7:19 pm #40722 robbo1973Participant had a job thru as no heat and leaking stat kit prob but are there any common probs with leaking ?just to take correct parts. Regards chris November 3, 2008 at 7:22 pm #267324 helo_75Participant drain channel blocked? faulty/jammed float switch.. cracked base (rare) the float switch is designed to turn the heater off, so thers no more condensing…. if it jams, it overfills…. thats if the pumps faulty of course November 3, 2008 at 7:25 pm #267325 smartinParticipant Re: ctd00 channel to pump chamber blocked flooding reservoir in bottom and blowing water onto elements usually, but take a pump just in case November 3, 2008 at 7:26 pm #267326 smartinParticipant Re: ctd00 😆 snap November 3, 2008 at 7:37 pm #267327 helo_75Participant Re: ctd00 😉 Author Posts Viewing 5 posts - 1 through 5 (of 5 total) You must be logged in to reply to this topic. Log In Username: Password: Keep me signed in Log In