AEG heater testing

Viewing 5 posts - 1 through 5 (of 5 total)
  • Author
    Posts
  • #40928
    Threeways
    Participant

    No heating on AEG Favorit 40850 (911 232 632 01). Have checked PCB board but can find no bad contacts/burn marks. Have removed heater to test but where do I measure resistance – is it across +ve -ve terminals? Thanks in advance.

    #268059
    Penguin45
    Participant

    Re: AEG heater testing

    Threeways wrote:is it across +ve -ve terminals?

    Yup – 25-30 ohms is typical.

    Power off first, please.

    Penguin45.

    #268060
    Threeways
    Participant

    Re: AEG heater testing

    Thanks. There’s no resistance across terminals so I suspect heater is faulty.

    #268061
    Penguin45
    Participant

    Re: AEG heater testing

    You’ll need THIS then.

    Penguin45.

    #268062
    Threeways
    Participant

    Re: AEG heater testing

    Great. I will order forthwith.

Viewing 5 posts - 1 through 5 (of 5 total)