whirlpool american t/d leq8033

Home Forums Trade Technical & Spare Parts Forums Trade Technical Enquiries whirlpool american t/d leq8033

Viewing 3 posts - 1 through 3 (of 3 total)
  • Author
    Posts
  • #41216
    dealdd
    Participant

    i have installed two of these no and fitted a side ducting kit on both. they work fine on timed dry but never switch off on sensing dry. has any one had this problem ?

    #269157
    Tubs
    Participant

    Re: whirlpool american t/d leq8033

    Will do some research for you, have one of these at home but never use sensor dry.

    #269158
    Penguin45
    Participant

    Re: whirlpool american t/d leq8033

    From our colleagues over on ApplianceJunk.com:

    Depending on Model Number, during Sensor Dry, the Timer will not advance until the Operating Thermostat opens, which may be delayed if (on Electric Dryers), the incomimg voltage is low. (208v, etc)

    There are replacement Heater Coils for such voltages.

    Courtesy of their member RegUS_PatOff.

    Chris.

Viewing 3 posts - 1 through 3 (of 3 total)
  • You must be logged in to reply to this topic.