Customer called me today complaining his Asko T721 condensor is throwing its rear TOC after 5 mins or so. He apparently dragged this thing over from Norway where he used to live. Not sure if i’ve seen this animal before, anyone know if they suffer cycling stat issues & if so, where can i find it 😯 Or maybe its just blocked of course?? 😯 Thanks.
bound to be a blockage or loose fan issue I would think. One stat on the front under the removable panel, other ones on the heater. Whole back of machine comes off to access.
Just had same problem on Maytag version.
Lint filter is a very fine mesh in double layer, looks fine until you hold up to light when found to be blocked. Good scrub under tap soon sorted.
Also the fan can be accessed from front after fan cover is removed. Blades badly fluffed up.Vacuumed out fan chamber and ducting now all working fine.
Cheers for that, was supposed to have looked at this today but my punter phoned to ‘pospone’ the call as something important had cropped up.. i shall look for the above if i get another invite.. :rolls: