    Hello, I have a Fisher and Paykel GW708U.

    When I start the machine it will fill with water correctly, and go through the wash cycle correctly. However once it gets to either the Rinse or Spin cycles the machine completely empties the water and then sits there and sort of vibrates and wont start the rinse.

    As per the sticky I put the machine into Diagnostic mode and got error 40 (101000). Any help you could give me would be very much appreciated. 😀

    #270861
    Penguin45
    Participant

    Re: F&P GW708U problem

    bigsmokepiker wrote:Bowl disengage fault
    While carrying out bowl check Controller has indicated the bowl has not engaged even though pressure switch has indicated bowl is empty
    Suggested actions
    1 Too many suds/ie to much detergent
    2 Check to see if bowl Is Lifting up & down Ok
    3 Check that clutch is not jammed & splines are not obstructed
    (To do this you will have to remove agitator from spline & plate under agitator.).
    4/Check pressure tube has not kinked or come off
    5 Could be a matter of a faulty motor controller(PCB)

    Yes there are alot of possible causes for this fault code

    Penguin45.

    #270862
    Dwingathond
    Participant

    Re: F&P GW708U problem

    Thanks for the quick response!

    I just went and lifted the bowl, and that seems ok, so I guess it must be one of the other problems.