indesit di 620

Viewing 2 posts - 1 through 2 (of 2 total)
  • Author
    Posts
  • #41795
    zakado
    Participant

    hello all
    excellent source of info great site

    so here we go after trawling throught the site i came to the conclusion a new pcb would fix my issue
    di620 not heating water and l4 flashing

    so tonight i replaced it and bingo during the test cycle hot water
    the problem is that when i tried to reset it has decided to stick at
    l2 and l3 flashing and wont let me reset

    this question has been asked but i cant find an answer
    think the last guy may still be pulling his hair out (lol)

    if anybody has a clue i would much appreciate it

    M B
    zakado

    #271357
    iadom
    Moderator

    Re: indesit di 620

    2 & 3 flashing is supposed to indicate a fill problem.

    Sometimes removing the new module and inserting the old one before re inserting the new one can force a reset.

    There are two different modules for this machine dependant on serial number. They are not interchangable.

    Before serial number 6102.0000 it is a C00143206, after serial number 6102.0001 it is a C00143222.

    Also worth checking the heating element for earth leakage as this can throw up spurious faults.

    Jim.