Hotpoint CTD40

Viewing 3 posts - 1 through 3 (of 3 total)
  • Author
    Posts
  • #42167
    Specialist01269
    Participant

    Hi Guys: Not done 1 of these heaps before so would appreciate some advice. Reported problem was no heat with lights flashing, looked at the machine today & it seems to have 2 faults: 1) No heat with lights flashing F13 which according to my book is rear NTC fault. Checked this, the 2 stats & the element all appear to be in order ie continuity across both stats & NTC reading 750k at room temp?.
    2) Machine will not turn off with the On/Standby button but only stops if you open the door.
    Am I missing something simple?.
    Andy. 😕

    #272593
    hotpnt
    Participant

    Re: Hotpoint CTD40

    you cannot switch off when in fault error, unless you open the door or disconnect power, if the NTC & wiring are all fine then it will be module fault, common fault with these

    #272594
    Specialist01269
    Participant

    Re: Hotpoint CTD40

    Hi Hotpnt: Thanks for the info it’s really appreciated. As i said this is the first one of these I have worked on so thought it better to ask for advice.
    1 question though: Is 750k at room temp acceptable for this NTC?
    Thanks again & Happy New Year: Andy. 🙂 🙂

Viewing 3 posts - 1 through 3 (of 3 total)