    Hi there everbody,

    My 1st post to the forum so here goes.

    The element has given out on my diplomat oven twice now in 2 years.
    If I get a new one are they easy to fit?

    Also if we decide to get a new oven I have noticed that the oven plugs into a standard 13amp plug socket. Will this effect what I buy in the future?

    Happy New Year.

    Slayer40

    I have just noticed a previous post that answered my element question (must use my eyes) But help on the 13amp plug socket would be helpful.

    😀

    #273208
    aqualectric
    Participant

    Re: Diplomat APL 3201X

    If it’s a single cavity oven and rated below 3000W then a 13 Amp plug is fine. Double ovens, however, must be hardwired. When both ovens are used at the same time, the current required would far exceed the design limit of a plug and socket.

    Hope that helps,

    Steve.