Does any one know what this fault equals please?
This machine was stuck full of water flashing C6. The water level was 3/4 of the way up the door.
Managed to empty the machine after setting the machine to drain about 20 times as it would only pump out for 15 seconds before flashing C6 every time.
Once the water level was below the bottom of the door glass the C6 fault stopped and it continued to drain until empty.
Customer had set machine on 40 degree delicate cycle and found water coming out of soap dispenser half way through the cycle.
After draining off water and looking over this machine the only fault I could find was a slightly blocked pump, so the only thing I can think of is that the machine failed to get rid of the wash water before taking in more water for a rinse. Any suggestions please.
Thanks Graham
Thanks Chris
She did have the same problem with this machine last November but another firm visited on that occasion,they changed the pump and removed some limescale according to the reciept.
Maybe I will ring her and suggest changing both pressure switches as the pressure hoses were ok and the pressure vessel was free of lime scale.
Graham.
Been back to this machine today and heater reads 2 Meg ohms to earth after it has been on for 20mins. So ordered a new heater but had a choice of two, a 240v element or 230v element. I have ordered the 240v one. can anyone explain the choice of two? 😕
Graham