Beko WMA 520s w/m blowing fuses

Home Forums Trade Technical & Spare Parts Forums Trade Technical Enquiries Beko WMA 520s w/m blowing fuses

Viewing 7 posts - 1 through 7 (of 7 total)
  • Author
    Posts
  • #44139
    nospin
    Participant

    Hi, just after the door lock closes, the rcd in fuseboard blows. I have checked element and motor. unplugged drain pump and fitted new door lock. Checked module for any burning and all clear. You can turn machine on, lights come on. It blows as soon as door lock operates. The capacitor is ok as well. also checked the wiring. Has anyone come across this please?

    #279914
    maltheviking
    Participant

    Re: Beko WMA 520s w/m blowing fuses

    Could be a faulty RCD though I doubt it, have you tryed anything else in the same socket?
    I presume you have meggered the various components and all is well? Any of the wiring damaged? You have checked the module for burning but have you checked to see if any of the components have blown, triacs etc?

    #279915
    nospin
    Participant

    Re: Beko WMA 520s w/m blowing fuses

    I feel like i have covered everything. Done all of the above. I repair quite a few bekos but have never had to look too deep. Was wondering what the pcb does as soon as lock is energized. Some do a little diagnoses. when i took the board out, i looked on both sides of the board and no signs of burning. The controls seem to work. i already ran on drain only cycle with the pump unplugged and the same thing happened. i did a test on the motor and seemed ok too. The RCD is ok as well as i tested the circuit. This has got me scratching my head. Many thanks

    #279916
    maltheviking
    Participant

    Re: Beko WMA 520s w/m blowing fuses

    Bad manners of of me Nospin 😳 Welcome to the madhouse :rotl:

    #279917

    Re: Beko WMA 520s w/m blowing fuses

    When you say the capacitor is ok, do you mean the radio interference filter? If so, what have you done to test it? The Beko’s I have seen all used a similar one to that used in Hoover Performa etc. They have a tendency to blow trips, sometimes intermittently. It is passing more current the moment the door locks. If you don’t have a spare to try in, you could just take it out of circuit temporarily.
    Mike.

    #279918
    nospin
    Participant

    Re: Beko WMA 520s w/m blowing fuses

    Thankyou, i will try that as i am going back to try again. many thanks and thanks for the welcome

    #279919
    nospin
    Participant

    Re: Beko WMA 520s w/m blowing fuses

    Thanks gents. Plugged in new motor and ok. Fault didn’t show on my megger. getting my megger tested i think. Cheers