Hotpoint WMA50P won’t fill

Home Forums Trade Technical & Spare Parts Forums Trade Technical Enquiries Hotpoint WMA50P won’t fill

Viewing 4 posts - 1 through 4 (of 4 total)
  • Author
    Posts
  • #44279
    Martin
    Participant

    Set it to wash and it just tumbles continually in one direction, it won’t fill. It won’t spin either just pumps and tumbles. Pressure hose clear and pressure switch clicks OK. Heater fine, brushes fine, valves OK. 😕

    Has anyone got a manual/wiring diagram please I think I need to delve deeper when I’ve got more time on this one……Thanks. 😀

    #280451
    iadom
    Moderator

    Re: Hotpoint WMA50P won’t fill

    Winging its way throught the ether as I type this. 😀

    Jim.

    #280452
    Martin
    Participant

    Re: Hotpoint WMA50P won’t fill

    Thanks Jim…nice one….will get back to you when I’ve sussed it out…cheers! 😀

    #280453
    Martin
    Participant

    Re: Hotpoint WMA50P won’t fill

    Update:

    Broken wire on Pressure Switch (Black lead -terminal 16 -snapped from its Rast type connector). As the Pressure Switch is tight up to the dispenser hoses I guess vibration cause the break. Hard wired using AMP tags sorted it….thanks again Jim. 😀