March 18, 2009 at 3:20 pm #44344
Goatboy
ParticipantHello 🙂
Got a Miele T294C CTD that’s not heating. It’s running for a few minutes then goes into fault mode.
The sensor on the heater has very little continuity through it, almost nothing. Is this normal, or should I just get a new one ordered at £30 a pop?
Part: 5435971
March 18, 2009 at 6:45 pm #280690PGS
ParticipantRe: Miele CTD
Nine out of ten its the TOC. Remember to test it with laundry in.
March 18, 2009 at 7:25 pm #280691Goatboy
ParticipantRe: Miele CTD
PGS wrote:Remember to test it with laundry in.
Aye, have done.
It goes backwards and forwards for a minute weighting the load, then you hear a relay click on the little heater pcb, but there’s no neutral going to the heaters. TOC tests fine 😕
After a few minutes it beeps and flashes the ‘machine iron’ light, which I think is the 3rd light down.
March 18, 2009 at 7:59 pm #280692clayside
ParticipantRe: Miele CTD
Third light down is fill ring temp sensor open or short circuit.
Part no 3887587 £34.08.
claysideMarch 18, 2009 at 8:38 pm #280693Goatboy
ParticipantRe: Miele CTD
Just had a check, and it’s the second light down, sorry :duck:
March 19, 2009 at 8:31 am #280694philfish
ParticipantRe: Miele CTD
They have a big heater relay and its not on the pcb. But chances are its the toc check for blockages ventilation etc ive also seen the fans block up with dog hair etc which restricts circulation.
phil
March 19, 2009 at 8:51 am #280695clayside
ParticipantRe: Miele CTD
Second light down is heater bank NTC open or short circuit
part no 5435971. claysideMarch 19, 2009 at 8:59 am #280696Goatboy
ParticipantRe: Miele CTD
THANK YOU everybody 😀
March 23, 2009 at 3:42 pm #280697Goatboy
ParticipantRe: Miele CTD
🙁 Cr@ppers!
New sensor hasn’t fixed it! The TOC is fine, new sensor, I stripped the thing down, and there’s no blockages anywhere.
Everytime (any heat prog.) after 2 minutes, it goes into fault, and it flashing 2nd light down (machine iron).
Anyone have any sugguestions?
March 24, 2009 at 7:08 pm #280698Goatboy
ParticipantRe: Miele CTD
Joy!
Twas one of the relays on the PCB. There’s a little PCB for the heater. Two lives and a neutral, and the neutral relay wasn’t switching 😕
March 31, 2015 at 10:19 am #280699Goatboy
ParticipantRe: Miele CTD
MORNING PEOPLE!
Did a search for Miele CTD, and found my own old post.
Does anybody know how to put these machines into test mode?
…Goatboy Senior is asking, having spend a day p*ssing around with this appliance.Or fault codes? 2nd & 5th light.
It is heating slightly, but goes into fault after 1 minute.
FANKS :tup:
-