Home › Forums › Trade Technical & Spare Parts Forums › Trade Technical Enquiries › How does the latest safety valve work?
- This topic has 4 replies, 3 voices, and was last updated 17 years ago by
Martin.
-
AuthorPosts
-
March 20, 2009 at 5:14 pm #44404
Martin
ParticipantMany of the later dishwashers have external valves that are coupled to the stopcock. (Bosch/AEG/Zanussi etc) Earlier versions incorporate a water block that involves a pressure tube that runs all the way back to the fill matrix to stop water flow. The latest ones don’t include this tube, they just have what appears to be 2 solenoids?……………..How the hell do they work? 😕
March 20, 2009 at 7:18 pm #280880Seamy
ParticipantRe: How does the latest safety valve work?
To be sure – to be sure is the Oirish answer to that.
Solenoids are in sequence on some, one after the other, if anything was to get trapped in seal seating & allow water to flow through the other solenoid should stop it.
March 20, 2009 at 9:50 pm #280881nationalhomecare
ParticipantRe: How does the latest safety valve work?
Machines destined for the german market have to have these ‘Aquastops’ its a requirement that the water is isolated at the point of entry from the tap, if the hose becomes damaged there should be no uncontroled leakage onto the floor.
The theory with the BSH ones is that if the tap leaks it goes into the couragated aquastop hose and back into the machine to operate the antiflood device, this is why they are specific on the orientation of the aquastop valve to the tap, all the valves in aquastop hoses are potted to prevent moisture ingress, if you change one you must heat shrink the cables with the connectors provided or change the whole assembly.All this said, it never stops mice chewing through the drain hoses!!
I really must get out more often…….
Steve
March 21, 2009 at 8:41 am #280882Martin
ParticipantRe: How does the latest safety valve work?
So it’s just a double solenoid wired in parallel then. 🙂
March 22, 2009 at 8:55 am #280883Seamy
ParticipantRe: How does the latest safety valve work?
Martin wrote:So it’s just a double solenoid wired in parallel then. 🙂
In the Miele waterproof version that i’ve seen most of in my work there are two separate solenoids wired in parallel but the pipework is obviously in series, this coupled by double walled hose & a float switch which brings on drain pump. They waterproof system will only work when machine is switched on the door closed though.
-
AuthorPosts