    rogerjet
    Participant

    Hi,

    Apologies as this could be a double post. I posted last night but I can’t see the post so I am posting again.

    I came home to a beeping washing machine (it had been off).

    It has 0011001 code 49 inlet valve fault (advice from F&P).

    The machine just beeps and displays code unless I unplug the machine. When plugged back in beeps and code. If I press start lights go out beeping stops and I have lid lock light flickering.

    I have measured the resistance of the cold and hot water valves and they are 61 and 63 ohms respectively.

    What I am wondering, is the problem the valve or controller.

    Thanks in advance for any help.

    #281433
    Penguin45
    Participant

    Re: Fisher Paykel GW611 code 49

    Cold water valve fault. Possible faulty wiring or connections; solenoid may be o/c – use test meter to check. Coil should read 64ohms.

    Penguin45.

    #281434
    rogerjet
    Participant

    Re: Fisher Paykel GW611 code 49

    thanks

    i have tested both valves by applying voltage directly to the coil. both opened and let water.

    im guessing it must be the controller. i checked the wiring all looks ok.

    any other ideas

    thanks

    #281435
    Penguin45
    Participant

    Re: Fisher Paykel GW611 code 49

    Motor controller is a possibilty – it uses a triac drive for the valves. If you are a suitably cunning artificer, you might like to apply power to the valve through the loom and see if it still works. Failing that, yes, the pcb.

    Penguin45.

    #281436
    rogerjet
    Participant

    Re: Fisher Paykel GW611 code 49

    Thanks for the help penguin.

    I tried applying power through the loom and valve still works.

    I have ordered a new controlller. 😥

    Does anything need to be done when installing a new conroller?

    #281437
    rogerjet
    Participant

    Re: Fisher Paykel GW611 code 49

    Hi,

    Having a problem with this damn machine again. New board in and about 10 washes no problem.

    Today it overfilled ie water all over the laundry quickly had to put it into spin to stop it taking water and drain.

    Any ideas what this fault could be? I have no fault code coming up and when I installed the new board I set the size to 6.5kg. I have checked the size now and still ok for 6.5kg.

    Any further help appreciated.

    #281438
    jophil29
    Participant

    Re: Fisher Paykel GW611 code 49

    Try the pressure tube connection to the new PC board.