The above m/c is a servis. The problem is that when prog is selected the fill pulses 1 sec on 1 sec off. Ive megered all components and replaced interlock and pressure s/wchecked for blockages and leaks on press system. Even hung a motor on but exactly the same. Seems to be pointing to module but ive never had this fault, so confimation would be helpful before I order. Cheers Paul.
PGS wrote:The above m/c is a servis. The problem is that when prog is selected the fill pulses 1 sec on 1 sec off. Ive megered all components and replaced interlock and pressure s/wchecked for blockages and leaks on press system. Even hung a motor on but exactly the same. Seems to be pointing to module but ive never had this fault, so confimation would be helpful before I order. Cheers Paul.
check heater ? if not that might be module wht not try e.m.w.