Diplomat 8552 washing machine

Home Forums Public Support Forums Help And Support Washing Machine Help Forum Diplomat 8552 washing machine

  • This topic has 2 replies, 3 voices, and was last updated 17 years ago by roz.
Viewing 3 posts - 1 through 3 (of 3 total)
  • Author
    Posts
  • #44746
    roz
    Participant

    Hi I have a Diplomat 8552 Washing Machine. The 4 wires on the back of the machine from the Thermostate have come off. I have two small white wires with TH on them, and also 2 grey wires with T90 on them. I am unable to find any markings on the thremostate which tellls me which way
    the wires have to be put back on.
    The two white wires go back to the circut board, and one grey wire goes back to the heater element. The other Grey wires goes to the pressure switch. Can you please help me…If possible can you email the reply.

    Thanks
    Roz

    #282164
    Penguin45
    Participant

    Re: Diplomat 8552 washing machine

    You need a test meter. The “thermostat” is a combination thermister and cut-out. Using the meter, the cut-out terminals will give a reading of virtually zero ohms. The thermister will give a reading in kOhms.

    Power off first.

    Penguin45.

    #282165
    karv
    Participant

    Re: Diplomat 8552 washing machine

    if u put them on wrong way u will blow the stat and melt it and blow 50/50 chance of blowing the board , and im not going to admit to how i know that information 😳

Viewing 3 posts - 1 through 3 (of 3 total)