NEFF S44T09N3GB/01 Home › Forums › Trade Technical & Spare Parts Forums › Trade Technical Enquiries › NEFF S44T09N3GB/01 This topic has 2 replies, 2 voices, and was last updated 16 years, 12 months ago by ChrisR. Viewing 3 posts - 1 through 3 (of 3 total) Author Posts April 16, 2009 at 5:10 pm #45042 ChrisRParticipant Hi guys. This dishwasher attempts to fill for a few seconds then goes in to outlet pump mode like the anti-flood was operating but its not. No water in base. Any ideas?. Thanks. Chris. April 17, 2009 at 7:33 am #283426 MartinParticipant Re: NEFF S44T09N3GB/01 Pressure chamber crudded up and red float inside sticking. Also check for gunge in sump transfer pipe. April 17, 2009 at 5:59 pm #283427 ChrisRParticipant Re: NEFF S44T09N3GB/01 Thanks Martin. Author Posts Viewing 3 posts - 1 through 3 (of 3 total) You must be logged in to reply to this topic. Log In Username: Password: Keep me signed in Log In