3 phase motor

Viewing 5 posts - 1 through 5 (of 5 total)
  • Author
    Posts
  • #45184
    dealdd
    Participant

    does any one know what the windings should measure on a 3 phase motor out of a whirlpool washing machine

    #283927
    PGS
    Participant

    Re: 3 phase motor

    Hi if you test between phases the resistance for example 1and 2 shoud be the same as 2 and 3 and 1 and 3 get the pattern.

    #283928
    dealdd
    Participant

    Re: 3 phase motor

    have done that and they all measure 4 ohm

    #283929
    Seamy
    Participant

    Re: 3 phase motor

    What was the problem with it ?

    Sometimes contactor/relays give problems (contacts burnt) so only supplys 2 phases then motor will only hum & not turn.

    #283930
    dealdd
    Participant

    Re: 3 phase motor

    sometimes turns. then others it really struggles like windings are binding up you can even hold the motor shaft to stop it from turning. i think its the control unit but werent sure if them readings from motor were correct

Viewing 5 posts - 1 through 5 (of 5 total)