  • #45483
    adv
    Participant

    displayin fa after few seconds of filling 11 flashes says optical water indicator fault in wee book.is this the fill matrix wi reed switch ?any help guys

    #285812
    silverbroom
    Participant

    Re: diplomat adp8332

    Stick ADP8322 in to search, plenty to read on the subject.

    silverbroom.

    #285813
    silverbroom
    Participant

    Re: diplomat adp8332

    Sorry that should read ADP8332

    #285814
    adv
    Participant

    Re: diplomat adp8332

    yeh but penguin says this model doent have an optical thing .mmm these dw arnt worth the hassel man nightmare plumbing in kitchen two cud be body swerve job 😆

    #285815
    adv
    Participant

    Re: diplomat adp8332

    come on guys footy finnished 😆

    #285816
    Penguin45
    Participant

    Re: diplomat adp8332

    Start with the water indicator in the sump (sludge/microswitch failure). If that doesn’t do it, check out the flow meter in the fill matrix.

    Penguin45.

    #285817
    adv
    Participant

    Re: diplomat adp8332

    water indicator is that the grid wi diaphram microswitch? 😆

    #285818
    Penguin45
    Participant

    Re: diplomat adp8332

    Yup.

    Chris.

    #285819
    adv
    Participant

    Re: diplomat adp8332

    ok went back clean grid not dirty anyway this kitchens a mare. fill hose joined as is cable an drain hose wat {e5d1b7155a01ef1f3b9c9968eaba33524ee81600d00d4be2b4d93ac2e58cec2d} it definately beein the fill matrix before order part an take bloody hing oot 😮

    #285820
    Penguin45
    Participant

    Re: diplomat adp8332

    Why take it oot? Remove decor door and lower cover plate. Remove plug from indicator, throw in a pan full of water and see if the microswitch has closed. Drain it and see if it’s opened. If it isn’t working, it’s a quarter turn twist fit, which you can do through the gap.

    If it’s working, you’ll be looking at the flow meter – then you will have to haul it out.

    Chris.

    #285821
    adv
    Participant

    Re: diplomat adp8332

    thats wat a hinks wrong the flow meter.11 flashes.wat the hell is an optical water indicator? is that the pressure switch in sump or the flow meter . me confused soz :rolls: