F&P smartdrive 703 problems

Viewing 5 posts - 1 through 5 (of 5 total)
  • Author
    Posts
  • #45947
    blkcrx
    Participant

    Hi, my F&P 703 wont fill, have taken hoses off and checked filters but they seem fine, the fill pressure looks really slow.. if i hold the lid just open while filling it looks like it’s not much more than a trickle coming in. Is there a diagnostic procedure i can try to see if there is a problem.


    Please HELP!
    TIA
    blkcrx

    #287743
    blkcrx
    Participant

    Re: F&P smartdrive 703 problems

    OK i found the diagnostic check instructions and went through with the test, i held down the temp down button while pressing power on, (i didn’t get 2 beeps) all lights lit up for about 2 seconds then it changed to water level high and low lit up. I then pressed spin until slow and hold when lit but it didn’t show any errors.

    blkcrx

    #287744
    Penguin45
    Participant

    Re: F&P smartdrive 703 problems

    Cold water valve is a 12v proportional fill device and is subject to problems. Good practice is also to check wiring and function of lid switch and out of balance switch – both are subject to corrosion and damp problems.

    Penguin45.

    #287745
    bigsmokepiker
    Moderator

    Re: F&P smartdrive 703 problems

    More than likely inlet valve Cold (Very common fault that they fill slowly)
    Part # 426143 ABout $45-$50 AUd

    #287746
    blkcrx
    Participant

    Re: F&P smartdrive 703 problems

    Thankyou Penguin45 and bigsmokepiker. I replaced the cold water inlet valve for $45aud and it’s working perfect again, glad it was such a simple thing to replace.


    Cheers,
    blkcrx.