    comin up e3 heater or ntc heater meters ok , wers this so called ntc? an are they pron to go ? help guys cheers? 😆

    #288990
    A1engineer
    Participant

    Re: beaumatic dw bdw13

    the ntc is right at the lower front has 4?? wires attached to it with blue insulators on them, im pretty sure this app has a screw in type 1 shot stat at the back right of the base(could be wrong tho).

    HTH.

    Kev.

    #288991
    adv
    Participant

    Re: beaumatic dw bdw13

    yep its got the srew in type to. cudnt get to that to check.tho wud have take hole thing out. they ntc pron to cause the no heat e3 fault?

    #288992
    A1engineer
    Participant

    Re: beaumatic dw bdw13

    they can but most of the time it has been the 1 shot.

    #288993
    lee8
    Participant

    Re: beaumatic dw bdw13

    Here is a trick to reach stat without removing apppliance.

    Be sure to switch off appliance 😆

    Remove black cover at base on right handside.

    Insert your arm through, you should be able to reach stat, remove wires and unscrew, reinsert and resecrew as well.

    Meter stat if O/C its roggered.

    If your arm is too large, add some fairy liquid to arm and slide.

    You`ll look like a vet with arm up cows behind, but can ensure its repaired in 4 minutes 23 seconds.

    Which when working for Baumatic in an area the size of Scotland, speed is important.

    #288994
    adv
    Participant

    Re: beaumatic dw bdw13

    i dont want to loose ma arm 😆

    #288995
    lee8
    Participant

    Re: beaumatic dw bdw13

    adv wrote:i dont want to loose ma arm 😆

    You won`t.

    Having said that some of the posts i`ve read on the site, it may prove unwise.