    Hey guys!
    The fridge works fine but the freezer has completely defrosted. There is only one compressor so i am confused as there is 2 t/stats on the pcb control unit. Could this be faulty or would be a systems fautl?

    The compressor is running and the dryer etc warm… just no ice on evaperator!!

    #290107
    BobHope
    Participant

    Re: HOTPOINT – FRIDGE FREEZER FFA74

    Hi Minge

    this model has a diverter valve fitted in the rear compressor compartment
    worth checking to see if it has voltage or open circuit, if its the valve it will need a system recharge after fitting.

    Bob.

    #290108
    spimps
    Participant

    Re: HOTPOINT – FRIDGE FREEZER FFA74

    An old magnet off a microwave is handy to drop over valve to check mechanical part of valve will open.
    BG

    #290109
    kevinlewis
    Participant

    Re: HOTPOINT – FRIDGE FREEZER FFA74

    BobHope wrote:Hi Minge

    this model has a diverter valve fitted in the rear compressor compartment
    worth checking to see if it has voltage or open circuit, if its the valve it will need a system recharge after fitting.

    Bob.
    On this hotpoint the fridge is getting too cold and the PCB look fine.
    There is a resistance around the coil but no voltage getting to it when tested. What voltage should there be? And should the voltage be present only when one of the compartments requires it?

    #290110
    BobHope
    Participant

    Re: HOTPOINT – FRIDGE FREEZER FFA74

    Kevin

    i have emailed you some info.

    Bob.

    #290111
    SteveATY
    Participant

    I have the same fault on a Hotpoint FFM74 – the customer is reporting that the fridge section is freezing milk etc. Any information would be really useful be I pay a visit.

    Cheers,
    Steve.

    #290112
    pup
    Participant

    Re: HOTPOINT – FRIDGE FREEZER FFA74

    fridge has got sensor built in i think may that faulty?

    #290113
    johnnyj
    Participant

    Re: HOTPOINT – FRIDGE FREEZER FFA74

    These are prone to internal leaks usualy from the aqnticondesation loop around the freezer, the divertor valves dont give much problems,jj