    I dont know if anyone can help with this one. I have been to a ctd40g today that is dead. No lights nothing. I have checked the door switch and it has power at the board but it wont do a thing.
    Its only 13 months old. Do the boards fail on these and if so is this something that happens?
    Cheers Ray

    #292833
    johnnyj
    Participant

    Re: Hotpoint CTD40G

    Stats on the heater machine goes dead when open circuit, this change came in about 18 months ago. jj

    #292834
    ray.t
    Participant

    Re: Hotpoint CTD40G

    Thanks for that. I will go and check again.
    Cheers Ray

    #292835
    abbots
    Participant

    Re: Hotpoint CTD40G

    i’ve got exactly the same problem on a CTD40P.

    it is not the door switch or the float switch or the stats above the heater.
    power down to the module .
    no lights ,no nothing.
    micro-switch on the consol PCB seems fine.
    no dry joints on either PCB i can see.
    i presume it’s one of the PCB’s.
    Is the lower power module just a case of replacing it?
    or do you have to buy the EPROM seperate and program it?
    any advise would be greatly appreciated.
    john

    #292836
    johnnyj
    Participant

    Re: Hotpoint CTD40G

    Did you change the stats i have had one i tested stats seemed okay but it still wouldnt power up, changed the stats and it started working. The change came in in August 2007, if the one shot fails it breaks the supply to the module.