  • #47622
    funbobby
    Participant

    currently flashing up f05 so cleaned out pump and hoses etc all very clean, customer just phoned up to say its doing it again is f05 def a pump out problem? not seen many of these to be honest.

    #294039
    Martin
    Participant

    Re: hotpoint aqualtis 169pm

    funbobby wrote: is f05 def a pump out problem?

    It could also relate to a Pressure Switch problem or wiring to and from it to the module. If you found nothing in the pump and drain system I would suggest that’s the next place to look. 🙂

    #294040
    funbobby
    Participant

    Re: hotpoint aqualtis 169pm

    turned out to be an id card that was blocking the sump hose at the drum end which must have been somewhere in the drum on the first visit, always the way!

    #294041
    simonb
    Participant

    Re: hotpoint aqualtis 169pm

    funny that iv been caught out with a very similar thing, cant remember what card it was but it was a card stuck in the sump on recall visit after changing the pump on same model iv just checked my job history to confirm it as well Hotpoint Aqual 169.

    EVERYBODY WATCH OUT this model chews cards maybe next one i meet ill try the wifes credit card??

    #294042
    johnnyj
    Participant

    Re: hotpoint aqualtis 169pm

    The sump balls have a habit of sticking causing this as well, i normaly take them out and throw them away the customers are none the wiser. JJ