The problem I have with this unit is every thing in the lower half freezes (not so bad in the upper half). setting is at 9 degrees and the wet wall has a thin layer of ice/frozen droplets of water.
Thermistor was reading 15k
I believe it may well be the board but was hoping that someone with more experiance of these units could confirm my thoughts.
Also where is the best place to get miele parts?
Would think its the sensor as @ 15k its reading 20c. At zero c it reads 38k
Part no of sensor kit is 7323300 £30.45 plus vat
Electronic is part no 6260821 £71.97 plus vat
From Miele 01235 233133