    cornwell40
    Participant

    Machine has E34 (through dignostics) intermittently coming up. About 30 seconds into fill the progress leds change from wash to drain, the machine display returns to 0 and the door unlocks. No blockages, but when I released the electronic switch the programme could be started again normally.
    Not too sure about this one but I’m suspecting the electronic switch.
    The other thing about this machine is that the board whines constantly, so could this be contributing to the fault 😕

    TC

    #294621
    neilsukwg
    Participant

    Re: Zanussi ZWF1437w E34

    pressure switch?

    In the ukwg manual E34 is not listed but all the other E30s listed are pressure switch faults.

    Not to sure about the whining though 😕 are you sure thats not your customer?

    #294622
    electrofix
    Moderator

    Re: Zanussi ZWF1437w E34

    e34 fault listed as

    Inconsistency between level on electronic
    pressure switch and level on anti-boiling pressure
    switch 2 (fault persists for at least 60 sec.).


    possible suggested cures

    pressure switch defective;
    Electrical current leak between heating element and ground; Heating
    element; Wiring defective;
    Main board defective.
    Water circuit;

    from lux disc

    hope this helps

    Dave