Zanuzzi Freezer ZUF105W (frost free)

Home Forums Trade Technical & Spare Parts Forums Trade Technical Enquiries Zanuzzi Freezer ZUF105W (frost free)

Viewing 5 posts - 1 through 5 (of 5 total)
  • Author
    Posts
  • #48810
    JOHN CLARKE
    Participant

    Evaporator iced up. De-frost heater OK, cut-outs OK, has anybody got any clues why this happens, does anybody have a wiring diagram please.

    #297802
    TheSpinDoctor
    Participant

    Re: Zanuzzi Freezer ZUF105W (frost free)

    Most likely the NTC temperature sensor has gone out of calibration. This happens when they absorb moisture & this causes the defrost cycle to be suspended, hence the excessive frost build up on the evaporator. The only thing other than that I can think of if you are correct in that the other components are OK is the main control board but I think this unlikely.

    I hope this is helpful to you.

    #297803
    trotter
    Participant

    Re: Zanuzzi Freezer ZUF105W (frost free)

    Blocked drain?

    #297804
    TheSpinDoctor
    Participant

    Re: Zanuzzi Freezer ZUF105W (frost free)

    Always possible but not likely. I have had this on more than one occasion & it’s usually the NTC.

    #297805
    JOHN CLARKE
    Participant

    Re: Zanuzzi Freezer ZUF105W (frost free)

    Thankyou for your replies, I’ll go for the thermistor (NTC), thanks again.

Viewing 5 posts - 1 through 5 (of 5 total)