miele dryer

Viewing 4 posts - 1 through 4 (of 4 total)
  • Author
    Posts
  • #48838
    superspin
    Participant

    hi all
    miele T234c tumble dryer

    called out to it today, fault was no heat ,found the thermostat on heater faulty so replaced and tested.

    i now have heat but dryer only runs for 20 seconds then the anticrease light flashes. this happens on timed dry aswell as sensor dry.

    good air flow,condensair box dirty but not blocked.

    this is my first miele dryer repair so ant help would be appreceated

    thanks wayne.

    #297885
    washermanuk
    Participant

    Re: miele dryer

    did you try it with some clothes in? these will end the programme without damp washing in? also check two carbon brushes on top of the drum for wear
    will try and get some tech info from work tomorrow fault codes etc cannot think off hand matey

    #297886
    superspin
    Participant

    Re: miele dryer

    thanks for the reply,no i didnt try it with any clothes in
    some more info would be good.

    ukwhitegoods erro code manual doesnt have any info on the miele condensair dryers.

    #297887
    electrofix
    Moderator

    Re: miele dryer

    to continue from washermanuk’s comments

    a lot of dryers these days sense the moiture in the clothes and turn off when dry to save energy

    either put some wet clothes in to try or look to see if there is a timed feature to turn dryer on for 20mins or so this normally does not use sensors so wont switch off

    hope this helps

    Dave

Viewing 4 posts - 1 through 4 (of 4 total)