Hi
Bosch WFK2801.
removed a bra wire from the sump.
On test if you select spin, the machine indicates 13 mins but only does a drain for 2 minutes.
If you select a 30 deg wash you get an 18 minute rinse with agitation.
On spin programme it doesnt matter which spin, the timer counts down and you dont get any agitation at all.
This occured prior to me removing the wire which she kindly informed me of after I had removed the wire and replaced the worn FHP brushes.
Checked the usual stuff but it was a late call last night. Am I missing something simple here? 😕