INDESIT R 24

Viewing 4 posts - 1 through 4 (of 4 total)
  • Author
    Posts
  • #49015
    DDSDDS
    Participant

    was called out to the above machine told that it just kept on running and running and freezing the milk duly replaced thermostat only to be told as i was leaving that there was another fault with the bulb intermitantly working had a quick look and all seemed fine
    got a call back today says it is exactly the same compressor is constantly running
    freezer is around -32 and fridge about – 4 the light works sometimes but not others and yes i have checked the lightswitch
    any ideas anyone?

    #298499
    DDSDDS
    Participant

    Re: INDESIT R 24

    left this on overnight and its still running
    – 10 in fridge and – 38 in freezer
    what are the chances of a faulty stat??
    and would that cause the lamp to only work when it feels like it

    #298500
    DDSDDS
    Participant

    Re: INDESIT R 24

    just thought i would update my progress in case it helps anyoone else in the future
    i decided to have another look at this fridge yesterday afternoon i went to look at the relay to see if anything was at fault there
    when i looked closely i realised that the mains cable had been replaced upon inspection the live in was put directly onto the common hence the fridge was always running and the light only worked for a few hours when first plugged in
    turns out the fellah whose fridge it is had changed it for a longer
    then the fault starts
    makes you wonder why he did not feel it relevant to tell me that in the first place

    #298501
    washermanuk
    Participant

    Re: INDESIT R 24

    This should be in The most annoying things our lovely customers do!!!! 😆