    dealdd
    Participant

    been out to this diplomat d/w. its the same as the whirlpool inside. when you turn it on it fills quickly then it just bleeps at you the start light flashes once which i think is a thermistor error can any one help. ???
    i have had this before and i put new pcb and thermistor in and still didint fix the fault??? adp8322 854500015810

    #298785
    electrofix
    Moderator

    Re: diplomat d/w adp8322

    yes light continually flashing with no break is 1 flash and therfore ntc fault

    i have had the same thing got 1 flash changed ntc no change i keep 1 to try now as a test

    Dave

    #298786
    dealdd
    Participant

    Re: diplomat d/w adp8322

    do you know what ntc should measure?? i had one kicking around on van but not sure if it was faulty as when i fitted it fault was still there

    #298787
    jackster
    Participant

    Re: diplomat d/w adp8322

    Redings below:

    20 Degrees Celcius = 58.1 kohms
    25 = 47.1
    30 = 38.2
    40 = 25.4
    50 = 17.2
    60 = 11.8
    70 = 8.3
    80 = 6
    85 = 4

    Hope this helps.
    Chay

    #298788
    dealdd
    Participant

    Re: diplomat d/w adp8322

    ok cheers lads i will fit a thermistor an see how it goes. if anyone comes up with any ideas in mean time please let me know