Home › Forums › Trade Technical & Spare Parts Forums › Trade Technical Enquiries › Miele Novotronic T240 Air Vented T/D
- This topic has 10 replies, 6 voices, and was last updated 16 years, 6 months ago by
mike100.
-
AuthorPosts
-
October 6, 2009 at 3:01 pm #49118
mike100
ParticipantFault is no heat. No power to heater.
Cable from heater goes to module, could that be where fault is?
Any help appreciated please.
Mike
October 7, 2009 at 6:10 pm #298801chitts
ParticipantRe: Miele Novotronic T240 Air Vented T/D
T.O.C. is most common fault (175deg.). Module VERY rare.
October 8, 2009 at 9:40 pm #298802mike100
ParticipantRe: Miele Novotronic T240 Air Vented T/D
Theres no power to toc on top of heater if that is the one you mean.
Is there another one?
mike
October 8, 2009 at 10:03 pm #298803philfish
ParticipantRe: Miele Novotronic T240 Air Vented T/D
Is there a seperate heater on this model miele usually put seperate relays on there machines just a thought.
Phil
October 8, 2009 at 10:03 pm #298804washermanuk
ParticipantRe: Miele Novotronic T240 Air Vented T/D
Hi Matey it is the one above heater “Blue spot”
Cause for this restricted air flow, filters etcOctober 9, 2009 at 8:32 am #298805admin
KeymasterRe: Miele Novotronic T240 Air Vented T/D
washermanuk wrote:Hi Matey it is the one above heater “Blue spot”
Cause for this restricted air flow, filters etcive been to 3 of these and every time its been the one above heater…
just test with meter….and you will see its dead…canufixit
October 9, 2009 at 1:25 pm #298806mike100
ParticipantRe: Miele Novotronic T240 Air Vented T/D
Thanks guys but theres no power to the to the toc.
Any other ideas?
October 9, 2009 at 4:32 pm #298807russell555
ParticipantRe: Miele Novotronic T240 Air Vented T/D
are you testing it with a damp load in??? as machine will not activate heater until dampness is present
October 9, 2009 at 5:09 pm #298808mike100
ParticipantRe: Miele Novotronic T240 Air Vented T/D
No, didn’t test with anything in. Going back.
Thanks,
MikeOctober 12, 2009 at 2:34 pm #298809mike100
ParticipantRe: Miele Novotronic T240 Air Vented T/D
Gone back and tested with damp clothes in. Intermittant power comes to TOC but is showing double positive.
Have taken off relay next to module and there are signs of burnt contacts.
Could that be the problem. Part No. is 4028320 Relay.
Don’t want to spend £60 odd if I am barking up wrong tree.
Cheers
Mike
October 13, 2009 at 6:08 pm #298810washermanuk
ParticipantRe: Miele Novotronic T240 Air Vented T/D
Most likely relay matey no way of checking it with a meter?
-
AuthorPosts
- You must be logged in to reply to this topic.
