  • #49118
    mike100
    Participant

    Fault is no heat. No power to heater.

    Cable from heater goes to module, could that be where fault is?

    Any help appreciated please.

    Mike

    #298801
    chitts
    Participant

    Re: Miele Novotronic T240 Air Vented T/D

    T.O.C. is most common fault (175deg.). Module VERY rare.

    #298802
    mike100
    Participant

    Re: Miele Novotronic T240 Air Vented T/D

    Theres no power to toc on top of heater if that is the one you mean.

    Is there another one?

    mike

    #298803
    philfish
    Participant

    Re: Miele Novotronic T240 Air Vented T/D

    Is there a seperate heater on this model miele usually put seperate relays on there machines just a thought.

    Phil

    #298804
    washermanuk
    Participant

    Re: Miele Novotronic T240 Air Vented T/D

    Hi Matey it is the one above heater “Blue spot”
    Cause for this restricted air flow, filters etc

    #298805
    admin
    Keymaster

    Re: Miele Novotronic T240 Air Vented T/D

    washermanuk wrote:Hi Matey it is the one above heater “Blue spot”
    Cause for this restricted air flow, filters etc

    ive been to 3 of these and every time its been the one above heater…
    just test with meter….and you will see its dead…

    canufixit

    #298806
    mike100
    Participant

    Re: Miele Novotronic T240 Air Vented T/D

    Thanks guys but theres no power to the to the toc.

    Any other ideas?

    #298807
    russell555
    Participant

    Re: Miele Novotronic T240 Air Vented T/D

    are you testing it with a damp load in??? as machine will not activate heater until dampness is present

    #298808
    mike100
    Participant

    Re: Miele Novotronic T240 Air Vented T/D

    No, didn’t test with anything in. Going back.
    Thanks,
    Mike

    #298809
    mike100
    Participant

    Re: Miele Novotronic T240 Air Vented T/D

    Gone back and tested with damp clothes in. Intermittant power comes to TOC but is showing double positive.

    Have taken off relay next to module and there are signs of burnt contacts.

    Could that be the problem. Part No. is 4028320 Relay.

    Don’t want to spend £60 odd if I am barking up wrong tree.

    Cheers

    Mike

    #298810
    washermanuk
    Participant

    Re: Miele Novotronic T240 Air Vented T/D

    Most likely relay matey no way of checking it with a meter?