Hoover/Candy CMD146-80

Viewing 3 posts - 1 through 3 (of 3 total)
  • Author
    Posts
  • #49189
    Dales-Electronic
    Moderator

    Got power into the machine and out of the suppressor but everything else is dead. Suspect either the timer or module at fault. Anyone got any ideas.

    #299045
    timdowning
    Participant

    Re: Hoover/Candy CMD146-80

    Had one where the pump was open circuit.

    But generally the module is at fault.

    #299046
    aqualectric
    Participant

    Re: Hoover/Candy CMD146-80

    Probably main PCB. 😥

    Look for:-

    1) Green corrosion on the selector unit connections caused by poor lid sealing – can blow the PCB;
    2) Water traces on the pump (blows the board);
    3) Ribbon cables chafing on the motor mounts; shorting out to earth and blowing the PCB.

    Lovely machines these Candy offerings………. 👿 EMW repair and reprogram these boards. Some new ones are supplied non – configured, so watch out for that. 😉

    Hope that helps,

    Steve.

Viewing 3 posts - 1 through 3 (of 3 total)
  • You must be logged in to reply to this topic.