    Hi , problem with a Otsein blowing rcd’s.I removed it from the house it was in as the wiring in the house is typical spanish spec(no earth wire).On retest the machine will wash approx 40mins, then will trip the rcd.The pump is running but does not empty.After draining manually i can get the machine to spin.I have cleared the pump(nothing found).The machine is 9years old and there is rust on the pump.I’m 99{e5d1b7155a01ef1f3b9c9968eaba33524ee81600d00d4be2b4d93ac2e58cec2d} sure the pump is causing the problem,but is there anything obvious i may have missed?

    The machine is an Otsein lt451 PNC 37506169/00380455
    Thanks

    #300280
    kwatt
    Keymaster

    Re: Otsein blowing house circuits

    Hi,

    Pump is a possibility yes but, can you tell us what stage the machine is at when the trip goes as that could provide a vital clue or two?

    K.

    #300281
    spanishwhite
    Participant

    Re: Otsein blowing house circuits

    Hi Kwatt, just as it is about to drain prior to rinse.

    #300282
    kwatt
    Keymaster

    Most likely it is the pump then I’d reckon.

    K.

    #300283
    spanishwhite
    Participant

    Re: Otsein blowing house circuits

    Thanks again.