Hotpoint dishwasher DF23

Viewing 3 posts - 1 through 3 (of 3 total)
  • Author
    Posts
  • #49579
    Dales-Electronic
    Moderator

    Must be getting old cos I should remember this one 😀 Set dishwasher to program three, appliance pumps out water and then stops. The inlet valve is buzzing and there is water to it, I have checked as this one has a pressure pipe attached to inlet valve that this is clear but no water is entering the appliance. Help 😳

    #300309
    timdowning
    Participant

    Re: Hotpoint dishwasher DF23

    Clean out the black sump hose.

    If that doesn’t cure it replace the valve assy.

    Don’t think theres anymore to it than that?

    (For testing purposes you can slave in a normal single valve.)

    #300310
    iadom
    Moderator

    Re: Hotpoint dishwasher DF23

    At this age its not uncommon for the inlet valve diaphragm to split. I often strip the valve down and replace the bits & bobs from a new, bog standard solenoid valve.

    Jim.