    PGS
    Participant

    Hi customer called saying steam was escaping from detergent drawer when on tumble dry. Any pointers appreciated. cheers Paul.

    #300567
    iadom
    Moderator

    Re: Bosch WVT1260

    Steam from drawer on most washer dryers is normally due to an OC condensor solenoid valve.

    Did one on a Bosch only last week, managed to prise off the coil and fit one from a new single valve.

    #300568
    nomadPaul
    Participant

    If the condensor solenoid test ok , next stop is a blocked condensor box on the LHS . They can get blocked where the condensor box is attached to the drum …..not a job for the faint-hearted !!!

    #300569
    Hammertime
    Participant

    Re: Bosch WVT1260

    Let it run for 10 minutes, these valves like to work for a few minutes then stop. If you do need to get to the condenser at the bottom, take the front off, then lie it on its RHS, gives you a touch more room to play with.
    There is also something else that can cause this problem, never come across it myself so not 100 percent sure on this, but I think it is if the pipe from the little rectangular plastic chamber (where the water feeds from the valve) to the condenser chamber is too long. Like I said, Im not too sure about this, so hopefully someone else can clarify it.